HARMONICS

Active and passive harmonic filters

Harmonic mitigation needs to match the loads producing the distortion and the network supplying them. Distorted currents, overheating, neutral loading or compatibility issues may call for filtering. Active and passive filters offer different approaches, which must be assessed at the intended connection point and under actual operating conditions. THDI needs to be read alongside actual current, the harmonic spectrum and voltage distortion.

Active filters: controlled compensation

These measure currents and simultaneously inject compensating components at several harmonic frequencies, providing broadband compensation within the limits of the device. Compensation can respond within a few milliseconds, depending on the model and control mode. Measurement location, CT arrangement, available current and priorities between any additional functions affect the result.

Passive filters: dedicated circuits

These are networks of reactors, capacitors and, where needed, resistors. Once the filter is connected, compensation acts instantaneously, without waiting for an electronic controller; the circuit still has its own transients. Tuned filters normally act on one or more harmonic orders and frequencies close to their tuning points. Wider-band configurations and filters designed for particular converters are also available. Selection must consider resonance, harmonic loading from the supply and operation at different load levels.

How Studio PQM helps

Preliminary study of the electrical installation and targeted measurements to define the filter requirements and functional details. Support includes review of existing recordings, comparison of central filtering and measures at individual loads, and post-installation measurements to verify operation of the installed system and the results achieved.

Compare ranges and features · 2 configurations

General guidance by solution type, using a 400 V low-voltage supply as reference. Ranges summarise the ratings considered and do not imply that all combinations are available. Connection, rating and actual performance must be checked for the project.

Active and passive filtering
ConfigurationRatings and supplyFeaturesChecks required
Active filter20–400 A; three-phase 400 V supplyMulti-frequency compensation; installation and modularity defined for the projectAvailable current, bandwidth and compensation priorities
Passive converter filter1.1–250 kW; three-phase 400 V supplyCircuits selected for the converter and harmonic spectrumLoad, supply impedance and performance at the relevant frequencies

The stated current is filter current, not total installation current. Residual distortion targets depend on the load, supply and verification conditions.

Already have measurements or a proposal? We can start there.

Discuss your case ↗